• 论文
主办单位:煤炭科学研究总院有限公司、中国煤炭学会学术期刊工作委员会
基于铁谱监测技术的采煤机设备故障诊断
  • Title

    Fault diagnosis of coal mining equipment based on ferrography monitoring technology

  • 作者

    崔智明

  • Author

    CUI Zhiming

  • 单位

    潞安化工集团有限公司

  • Organization
    Lu’an Chemical Group Co., Ltd.
  • 摘要

    分析了采煤机齿轮失效磨损形式,设计了基于铁谱技术的在线油液监测装置;结合目前煤矿机电设备故障诊断的情况,利用黏度与水分的监测与分析、磨损碎屑的监测与分析对煤矿机电设备中的金属元素进行检测,由此快速、准确地检测出设备内部的故障情况;并对煤矿机电设备常见的齿轮故障情况提出了相应的铁谱监测方案和诊断方法。

  • Abstract

    This article analyzed the failure and wear forms of coal mining machine gears, and designed an online oil monitoring device based on ferrography technology; based on the current situation of fault diagnosis in coal mine electromechanical equipment, the monitoring and analysis of viscosity and moisture, as well as the monitoring and analysis of wear debris, are used to detect metal elements in coal mine electromechanical equipment, to quickly and accurately detect internal faults of the equipment; the corresponding ferrographic monitoring schemes and diagnostic methods were proposed for common gear faults in coal mine electromechanical equipment.

  • 关键词

    铁谱监测技术在线油液监测装置齿轮故障诊断黏度与水分监测磨损粒子监测

  • KeyWords

    ferrography monitoring technology;online oil monitoring device;gear fault diagnosis;viscosity and moisture monitoring;wear particle monitoring

  • DOI
  • 引用格式
    崔智明. 基于铁谱监测技术的采煤机设备故障诊断[J]. 煤矿安全,2024,55(4):231−235.
  • Citation
    CUI Zhiming. Fault diagnosis of coal mining equipment based on ferrography monitoring technology[J]. Safety in Coal Mines, 2024, 55(4): 231−235.
  • 图表

    Table1

    监测预警标准及处理措施
    监测参数 监测预警值 磨损原因 处理措施
    污染度 ≥ 9 磨损出现异常性 对目前所使用的油进行更换,同时对磨损原因进行离线分析
    ≥ 10 磨损出现严重性 停止作业,对磨损原因进行离线分析
    黏度 ≥10%正常值 油液过度使用磨损出现异常性 对目前所使用的油进行更换
    水分 >0.5% 油液中水分掺杂过多 对目前所使用的油进行更换
    温度 >100 ℃ 载荷过大磨损出现异
    常性
    停止作业